Troubleshooting
Error code
Symbol
3109
3121
3123
3210
3220
3522
Error code 4000-4999: Error messages USB
4301
4304
Error code 6000-6999: Error messages displays
6351
6400
6952
Error code 7000-7999: Error messages displays
7200
Operating Instructions 745-35-10 S/745-35-10 A - 03.0 - 04/2017
Meaning
Safety stop activ
• Compressed air missing
• Compressed air insufficient
Oil level too low
• Thread broken left
• Thread broken right
• Empty bobbin left
• Empty bobbin right
Error Command Interpreter/Motor
synchronization Internal error
No USB key at the control unit
Wrong USB key
• USB key incompatible with
OP7000
• Capacity of USB key too large
Control error (I2C)
Internal error
Internal error step motor driver
Failure in CAN - Module corner
knife (AC001), no module
recognized at address
Remedial action
Switch the Safe stop off
• Turn on compressed air
• Stabilize compressed air
Top off the oil  p. 216
Insert thread  p. 19
Change bobbin  p. 23
• Switch off and on the machine
again
• Perform software update
 p. 208
• Feedback to Dürkopp Adler
Service
Insert USB key
Replace USB key
Replace the control
• Switch off and on the machine
again
• Perform software update
 p. 208
• Inform Dürkopp Adler Customer
Service
• Switch off and on the machine
again
• Perform software update
 p. 208
• Inform Dürkopp Adler Service
• Check cable
• Check jumpers
• Check voltage supply
239