Control System F ault C odes (softwar e v ersion H and up)
ID
Component
ID Name
1
Engine Can
13 Not
Bus
7
Engine
21 Fault
Warning
8
Engine Stop
21 Fault
10
Ground
27 Active at
Controls
Engine Start
Switch
11
Platform
27 Active at
Controls
Engine Start
Switch
12
Machine
13 Not
CAN Bus
Part No. 1286829GT
Cause
Engine CANBUS
detected
CAN+ or CAN-
shorted to supply.
The engine has
triggered the
Engine Warning
Lamp condition.
The engine has
triggered the
Engine Stop Lamp
condition.
Engine start button
startup
held at startup.
Platform controls
startup
engine start switch
active at startup.
Machine CANBUS
detected
CAN+ or CAN-
shorted to supply
S-40 XC • S-45 XC • S-40 TraX • S-45 TraX
Control System Fault Codes
Effect
Solution
Disable engine start
*Verify with a voltmeter that CAN+
for tier 4F engines
and CAN- lines are not shorted.*
Measure the resistance between
D228CAN+ (YL, TCON J9-3) and
D228CAN- (GR, TCON J9-4); should
be between 55 and 65 ohms.
* D228CAN+ (YL, TCON J9-3)
should be between 1V and 5V.
* D228CAN- (GR, TCON J9-4)
should be between 1V and 5V.
Remove short(s) and cycle power.
Machine will
* Check the engine fault codes with
function as normal.
an engine diagnostic tool.
Control system will
* Check the engine fault codes with
not allow engine
an engine diagnostic tool.
restart until power
Note: The control system shuts off
cycle. Engine may
the engine immediately upon
stop itself,
receiving this fault from the engine.
depending on the
engine option.
Engine start is
Release engine start button, check
disabled
DISCON overlay and ribbon cable if
issue persists.
Engine start switch
*Verify with a voltmeter that the
will not operate.
Engine Start Toggle Switch (TS2) is
operating properly.
* C33STR (BK, PCON J16-3) should
be 0 V with the switch OFF and 12 V
with the switch ON.
*Cycle power to allow the machine to
re-test the fault.
Machine will not be
*Verify with a voltmeter that CAN+
functional.
and CAN- lines are not shorted.
*Measure the resistance between
D82CAN+ (YL, TCON J5-3) and
D81CAN- (GR, TCON J5-4); should
be between 55 and 65 ohms.
*D81CAN+ (YL, TCON J5-3) should
be between 1V and 5V.
*D81CAN- (GR, TCON J5-4) should
be between 1V and 5V.
*Remove short(s) and cycle power.
Service and Repair Manual