Control System Fault Codes; How To Retrieve Control System Fault Codes - Platform Controls - Genie Z-40/23N Service And Repair Manual

Hide thumbs Also See for Z-40/23N:
Table of Contents

Advertisement

September 2016

Control System Fault Codes

How to Retrieve Control System
Fault Codes from the Platform
Controls
At least one fault code is present when the alarm at
the platform controls produces two short beeps
every 30 seconds for 10 minutes.
1
Turn the key switch to platform control.
2
Pull out the red Emergency Stop button to the
on position at both the ground and platform
controls.
3
Do not press down the foot switch.
4
Move and hold the drive enable toggle switch
in the right direction and hold the steer rocker
switch in the right direction.
5
When the display leaves SYSTEM READY
mode, release the drive enable toggle switch
and the steer rocker switch.
Result:The display will show FAULTS.
To access active faults:
6
Momentarily activate the drive enable toggle
switch in the right direction until ACTIVE
FAULTS is shown on the display.
7
Momentarily activate the drive enable toggle
switch in the right direction to access the
active fault codes.
8
Activate the steer rocker switch in the right
direction to scroll through the fault codes.
Part No. 1268528
Control System Fault Codes
To access motor controller faults:
9
Momentarily activate the drive enable toggle
switch in the right direction until ACTIVE
FAULTS is shown on the display.
10 Activate the steer rocker switch in the right
direction until MOTOR CONTROLLER
FAULTS is shown on the display.
11 Momentarily activate the drive enable toggle
switch in the right direction to access the
motor controller fault codes.
12 Activate the steer rocker switch in the right
direction to scroll through the fault codes.
13 Refer to the fault code table on the following
pages to aid in troubleshooting the machine by
pinpointing the area or component affected.
14 To exit the fault code screen, momentarily
activate the drive enable toggle switch to the
left direction until FAULTS is shown on the
display.
To exit programming mode:
15 Push in the red Emergency Stop button at the
platform controls. Wait approximately
5 seconds and then pull out the red
Emergency Stop button out to the on position.
Z-40/23N, Z-40/23N RJ