5894
5-894-001 SW Change Mode
5907
5-907-001 -
5930
5-930-001 Setting
5931
RTB 20
Modified
5-931-001 Mentenance Kit
5-931-002 PCDU
5-931-002 PCDU STOP
5987
5-987-001 0:OFF / 1:ON
5990
5-990-001 All
[ExternalCountSet]
Switch the Charge Mode of External Mech Count
[Plug & Play]
Selects the brand name and the production name for Windows Plug & Play. This
information is stored in the NVRAM. If the NVRAM is defective, these names should be
registered again.
After selecting, press the "Original Type" key and "#" key at the same time. When the
setting is completed, the beeper sounds five times.
[MeterClick Charge]
[Life Alert Disp.]
[Mech. Counter]
This SP detects that a mechanical counter device is removed. If it is detected, SC610
occurs.
[SP Print Mode]
Prints out the SMC sheets.
ENG*
[0 to 2 / 0 / 1/step]
CTL* [- / - / -]
ENG
[0 or 1 / 0 / 1/step]
*
ENG*
[0 or 1 / 0 / 1/step]
ENG*
ENG*
[0 or 1 / 0 / 1/step]
ENG
*
0: OFF. 1: ON
[- / - / -] [Execute]
CTL
Press "Execute" key to start printing the
SMC sheets.
Main SP Tables-5