6. Troubleshooting
No.
Type
FU3
Micro Fuse
Micro Fuse
FU7
282
Description
Protects the operation panel
from overcurrent
Protects the LEDA power
source from overcurrent
Symptom / Possible Cause /
Troubleshooting Procedures
Symptom:
• Although the power is applied to the
main machine, the operation panel
does not work
Possible Cause:
• Fuse blown out due to a short to ground
Troubleshooting Procedures:
• Replace the operation panel
• Replace EGB
Symptom:
• An LEDA-related error occurs.
Possible Cause:
• FFC is not connected properly.
Troubleshooting Procedures:
• Replace EGB
• Replace FFC
• Replace LEDA