table of contents
Owner's Information
Before You Start .......................................................................7
Warranty ................................................................................66
Unit Dimensions ......................................................................5
Installation
Information for Mobile/Manufactured Homes after First Sale ..3
Clearances ............................................................................16
On Demand Pilot (seven day safety timer)
Important information if using the appliance in CPI (continuous pilot
mode) only
This appliance is a ProFlame 2 system fitted with the "On Demand" Pilot, a
safety feature which will shut down the gas valve completely by extinguishing
the pilot light in the event of a continuous full seven days of inactivity.
This only applies if the CPI (continuous pilot) switch is in the "on" position in
your remote control transmitter.
Each time the main burner shuts down, manually or through the call from the
thermostat, the seven day timer starts again.
The seven day inactivity timer is controlled within the circuit board. Therefore,
if in CPI mode and when the pilot light is extinguished after seven straight
days of inactivity, the CPI setting on the remote control transmitter will remain
in the "CPI" (continuous pilot) position. Therefore, all that is required to relight
the pilot would be to press the on/off button on the remote control transmitter
from "on" to "off" and back to "on". Once the pilot has re-established operation
will resume as normal. There is no requirement to do anything with the IPI/CPI
mode on the remote control transmitter.
If the unit never goes as long as seven full days without a call for heat, the pilot
will remain lit until it is manually shut-off.
If the unit is being operated in IPI (intermittent pilot) mode, neither the above
instructions nor the seven day timer will apply.
See the instructions in this manual and on the Lighting Instructions plate on
the appliance to light or re-light the pilot.
|
4
Regency Excalibur
®
P90E-11 Direct Vent Gas Stove
tions Only ...............................................................................23
(part #946-755) ......................................................................38
System Data ..........................................................................40
High Elevation ........................................................................40
Flame Pattern ........................................................................40
Double Door Installation ........................................................51
Operation
First Fire ................................................................................55
Backup Battery ......................................................................56
Flame Pattern ........................................................................57
Log Replacement ..................................................................58
Glass Gasket .........................................................................58
Door Glass .............................................................................58
Fan Maintenance ...................................................................59
Main Assembly ......................................................................61
Warranty ................................................................................66