Venting
FPI Direct Vent System (Flex) Horizontal Terminations Only
These venting systems, in combination with the P90E-11 Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system by Warnock
Hersey/Intertek. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram in the "Exterior Vent Termination
Locations" section.
FPI Direct Vent (Flex) System Termination Kit
(Part # 946-515) includes all the parts needed
to install the P90E-11 with a maximum run
of 4 feet.
1. 6-7/8" dia. flexible liner (4 ft. length)
2. 4" dia. flexible liner (4 ft. length)
3. spring spacers (4)
4. thimble (2)
5. AstroCap termination cap (1)
6. screws (12)
7. tube of Mill Pac (1)
8. plated screws (8)
9. screws #8 x 1-1/2" Drill Point, Stainless
Steel (4)
4" dia. flue pipe
6-7/8"
(17 mm)
dia. Flue pipe
If a longer run is needed, the FPI Direct Vent
system (Flex) kit is 946-516 which includes
all the parts needed to install the P90E-11
with a maximum 10' run.
1. 6-7/8" dia. flexible liner (10 ft. length)
2. 4" dia. flexible liner (10 ft. length)
3. spring spacers (7)
4. thimble (2)
5. AstroCap termination cap (1)
6. screws (12)
7. tube of Mill Pac (1)
8. plated screws (8)
9. screws #8 x 1-1/2" Drill Point, Stainless
Steel (4)
Wall Thimble
(required in
Canada only)
5
Vinyl Siding
Standoff
(optional)
spring spacer
Regency Excalibur
Notes:
1. Liner sections should be
continuous without any joints or seams.
2. Only Flex pipe purchased from FPI may
be used for Flex installations.
3. Horizontal vent must be supported every
3 feet.
TM
AstroCap
Termination Cap
P90E-11 Direct Vent Gas Stove
®
installation
|
23