Copy Of Safety Decal For P90E-11 - Regency Excalibur P90E Zero Owners & Installation Manual

Clearance direct vent gas fireplace
Table of Contents

Advertisement

safety decal
This is a copy of the label that accompanies
each P90E-11 Zero Clearance Direct Vent Gas
Fireplace. We have printed a copy of the contents
here for your review. The safety label is located
on the front inside base of the unit, visible when
the bottom louver is open.
NOTE: Regency
units are constantly being
®
improved. Check the label on the unit and if
there is a difference, the label on the unit is the
correct one.

Copy of Safety Decal for P90E-11

Listed/Nom: VENTED GAS FIREPLACE / FOYER AU GAZ À ÉVACUATION
Certified to/Certifi :
MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE.
Refer to Intertek's Directory of Building Products for detailed information.
Pour plus de détails , se reporter au Répertoire des produits de construction de Intertek.
C #: 4001172
NATURAL GAS:
Model P90E-NG11
L
Minimum supply pressure
Manifold pressure high
Manifold pressure low
Orifice size
Minimum input
Maximum input
Altitude
PROPANE:
Model P90E-LP11
Minimum supply pressure
Manifold pressure high
Manifold pressure low
Orifice size
Minimum input
Maximum input
Altitude
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas and Propane Installation Code, CSA B149.1.
This appliance must be installed in accordance with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the United States, or
when such a standard is not applicable, ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard or ANSI A119.2 ou NFPA 501C Standard for Recreational Vehicles
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured (mobile) home where not prohibited by local codes. See owner's manual for
details. Optional Fan (Part # 910-331) Optional Heat Wave Kit # 946-556 Optional Heat Release Kit # 946-570
Installer l'appareil selon les codes ou règlements locaux, ou, en l'absence de tels règlements, selon les codes d'installation ANSI Z223.1, National Fuel Gas Code ou CSA-B149.1 en vigueur.
Installer l'appareil selon la norme CAN/CSA-Z240, Série MM, Maison mobiles ou CAN/CSA-Z240 VC, Véhicules de camping, ou la norme 24 CFR Part 3280, Manufactured Home Construction and Safety Standard. Si ces normes
ne sont pas pertinentes, utiliser la norme ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard, ou ANSI A119.2 ou NFPA 501C Standard for Recreational Vehicles.
Cet appareil doit être utilisé uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil peut être installé dans une maison préfabriquée ou mobile (É.-U. seulement) installée à demeure si les règlements locaux
le permettent. Voir le manuel d'utilisation pour plus de renseignements. Cet appareil ne peut pas être utilisé avec d'autres gaz sauf si une trousse de conversion certifiée est fournie.
This vented gas fireplace heater is not for use with air filters.
For use with glass doors certified with the appliance only
For Use Only with Barrier (Part #792-920) Follow installation instructions.
ELECTRICAL SUPPLY/ALIMENTATION ÉLECTRIQUE: 115V - 60HZ less than/moins de 2 AMP
VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUELS.
FOYER AU GAZ À ÉVACUATION -
CANADIAN ENERGY
CSA P.4.1 Fireplace Efficiency (FE) / Efficacité énergétique des foyers (EEF) CSA P.4.1
PERFORMANCE
VERIFIED
Natural Gas / Gaz naturel 71.36%
RENDEMENT
Propane Gas / Gaz propane 72.79%
ÉNERGÉTIQUE
EP5011169
VÉRIFIÉ
For the State of Massachusetts, installation
and repair must be done by a plumber or
Part #: 919-970
gasfitter licensed in the Commonwealth of
Colour: Everything black on grey except what is highlighted is printed red.
Massachusetts.
Material: 2 ml silver matt polyester (DPM SMS)
Size: 100% 9.88''W x 6.215''H
For the State of Massachusetts, flexible con-
Dec. 05/2018:
Created decal.
nectors shall not exceed 36 inches in length.
Feb. 20/19:
Updated standards & ETL logo
For the State of Massachusetts, the appli-
ances individual manual shut-off must be a
t-handle type valve.
The State of Massachusetts requires the
installation of a carbon monoxide alarm in
accordance with NFPA 720 and a CO alarm
with battery back up in the same room where
the gas appliance is installed.
|
6
Regency Excalibur
®
é
ANSI Z21.88-2017 • CSA-2.33-2017
CSA 2.17-2017
APPAREIL FONCTIONNANT AU GAZ NATUREL
Modèle P90E-NG11
5"
WC (1.25 kPa)
Pression d'alimentation minimale
3.5"
WC (0.87 kPa)
Pression manifold - haute
1.6"
WC (0.40 kPa)
Pression manifold - basse
Taille de l'orifice
# 34
DMS
D bit calorifique minimal
é
23,500
Btu/h (6.89 kW)
35,000
Btu/h (10.26 kW)
D bit calorifique maximal
é
0-4500
ft/pi
(0-1372 m)
Altitude
APPAREIL FONCTIONNANT AU GAZ PROPANE
Modèle P90E-LP11
11"
WC (2.74 kPa)
Pression d'alimentation minimale
10"
WC (2.49 kPa)
Pression manifold - haute
6.4"
WC (1.60 kPa)
Pression manifold - basse
Taille de l'orifice
# 51
DMS
D bit calorifique minimal
é
25,500
Btu/h (7.47 kW)
31,500
Btu/h (9.23 kW)
D bit calorifique maximal
é
0-4500
ft/pi (0-1372 m)
Altitude
Ne pas utiliser de filtre à air avec ce foyer au gaz à évacuation.
À utiliser uniquement avec les portes en verre certifiées avec l'appareil
Utiliser uniquement avec l'écran (pièce n° 792-920) Suivre les consignes d'installation.
NE PAS UTILISER AVEC UN COMBUSTIBLE SOLIDE.
Decal location
P90E-11 Direct Vent Gas Stove
496
DUPLICATE SERIAL NO.
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE
496
Minimum Clearances to Combustibles
Dégagements minimaux par rapport aux matériaux combustibles
44" To Ceiling
19"
6-1/2"
6-1/2"
(See Instruction Manual for
Detailed Instructions)
DOOR SEAL: Please check that the door is properly sealed
FPI Fireplace Products International Ltd.
Delta, BC, Canada
Made in Canada/ Fabriqué au Canada
Fold down access door by flipping down 90
have gained access the rating plate will be located on the
left hand side (see image below).
DO NOT REMOVE DECAL FROM UNIT.
Serial No./ No de série
0" Clearance to
combustibles from:
Top, bottom, sides & rear of unit
Mantel Clearances from Top:
Min. 19" (483mm)
Side Wall Clearance
from Side Facing
6-1/2" (165mm)
Alcove Clearances:
Max. Depth 36" (914mm)
Min. Width 72" (1829mm),
Min. Height 72" (1829mm)
Minimum Vent Clearances:
Horizontal Top
2-1/2" (64mm)
Horizontal Side
1-1/2" (38mm)
Horizontal Bottom 1-1/2" (38mm)