operating instructions
Aeration
Adjustment
The air shutter can be adjusted by moving the
adjusting wire up or down. The wire is accessed
through the bottom louver opening. Open the air
shutter for a blue flame or close for a more yellow
flame. The burner aeration is factory set but may
need adjusting due to either the local gas supply
or altitude.
Minimum Air Shutter Opening:
3/16"
Natural Gas
5/16"
Propane
CAUTION: Carbon will be produced if air shutter is
closed too much.
Note: Any damage due to carboning
resulting from improperly setting
the aeration controls is NOT covered
under warranty.
Note: Aeration Adjustment should only
be performed by an authorized
Excalibur
Installer at the time of
®
installation or service.
Adjustment Wire: Push to close or pull
to open aeration cap.
Closed - Tall yellow
Open - Short Blue
|