General Safety
Information
1. The appliance installation must conform with
local codes or, in the absence of local codes,
with the current Canadian or National Gas
Codes, CAN1-B149 or ANSI Z223.1 Installation
Codes.
2. The appliance when installed, must be
electrically grounded in accordance with local
codes, or in the absence of local codes with the
current National Electrical Code, ANSI/NFPA
70 or CSA C22.1 Canadian Electrical Code.
3. See general construction and assembly
instructions. The appliance and vent should
be enclosed.
4. This appliance must be connected to the
specified vent and termination cap to the outside
of the building envelope. Never vent to another
room or inside a building. Make sure that the
vent is fitted as per Venting instructions.
5. Inspect the venting system annually for blockage
and any signs of deterioration.
6. Venting terminals shall not be recessed into a
wall or siding.
7. Any safety glass removed for servicing must
be replaced prior to operating the appliance.
8. To prevent injury, do not allow anyone who is
unfamiliar with the operation to use the fireplace.
9. Wear gloves and safety glasses for protection
while doing required maintenance.
10. Be aware of electrical wiring locations in walls
and ceilings when cutting holes for termination.
11. Under no circumstances should this appliance
be modified. Parts that have to be removed for
servicing should be replaced prior to operating
this appliance.
12. Installation and any repairs to this appliance
should be done by a qualified service person.
A professional service person should be called
to inspect this appliance annually. Make it a
practice to have all of your gas appliances
checked annually.
13. Do not slam shut or strike the glass door.
14. Under no circumstances should any solid fuels
(wood, paper, cardboard, coal, etc.) be used
in this appliance.
15. The appliance area must be kept clear and
free of combustible materials, (gases and other
flammable vapours and liquids).
Installation
Checklist
1. Locate appliance, refer to the following sections:
a) Locating Your Gas Fireplace
b) Combustible Mantels
c) Unit Base Standoffs
d) Framing & Finishing
e) Facing Requirements
f)
Hearth Requirements
g) Venting
2. Assemble Top Standoffs, page 9. (Refer to the
"Unit Assembly Prior to Installation" section.)
NOTE: must be done before installing unit into
fireplace.
3. Install vent, refer to the "Venting" section.
4. Install 4-AA batteries into battery box. This will
enable operation of appliance manually when
in "ON" position.
5. Make gas and electrical connections. Test the
pilot. Must be as per diagram. Refer to the "Pilot
Adjustment" section.
6. Install standard and optional features. Refer to
the following sections where applicable:
a. Brick Panels
b. Log Set Installation
c. Arch Surround
d. Glass Door Installation
e. Remote battery box
(See instructions in manual)
7. Final check.
Before leaving this unit with the customer, the
installer must ensure that the appliance is firing
correctly and operation fully explained to
customer.
This includes:
1. Clocking the appliance to ensure the correct
firing rate (rate noted on label 35,000 Btu/h)
after burning appliance for 15 minutes.
2. If required, adjusting the primary air to ensure
that the flame does not carbon. First allow the
unit to burn for 15-20 min. to stabilize.
CAUTION: Any alteration to the product that
causes sooting or carboning that results
in damage is not the responsibility of the
manufacturer.