INTAKE (INDUCTION)

3. Air Cleaner Case

A: REMOVAL
1) Disconnect the ground cable from battery.
2) Disconnect the connector (A) of intake air tem-
perature sensor.
3) Remove the bolts (B) which install air cleaner
case to stay.
(B)
(A)
4) Disconnect the hoses and intake duct from air
cleaner case.
5) Loosen the clamp which connects air cleaner
case to throttle body.
6) Remove the air cleaner case.
B: INSTALLATION
Install in the reverse order of removal.
C: INSPECTION
Inspect for cracks and loose connections.