FUEL INJECTION (FUEL SYSTEMS)
7) Lower the vehicle.
8) Remove the sub service hole cover.
9) Disconnect the connector from fuel sub level
sensor.
10) Disconnect the fuel jet pump hose.
11) Remove the fuel sub level sensor.
FUEL
12) Drain the fuel from fuel tank by using a hand
pump.
WARNING:
Do not use a motor pump when draining the fu-
el.
13) After draining the fuel, reinstall the fuel sub lev-
el sensor.
Tightening torque:
FU-00445
NOTE:
If you have not removed the fuel tank yet, proceed
with the procedure below for installation.
(1) Connect the fuel jet pump hose.
FU-00446
(2) Connect the connector from fuel sub level
FU-00447
sensor.
FU-00448
FU(H4SOw/oOBD)-46
T: 4.4 N·m (0.45 kgf-m, 3.3 ft-lb)
FU-00448
FU-00447
FU-00446