Manual Regeneration Options

The Demand control features several options that
offer additional flexibility for manually regenerating
the conditioner.
Delayed Manual Regeneration
Pressing and releasing the REGEN button starts a
delayed manual regeneration. The Regeneration icon
on the display will flash indicating a regeneration will
start when the time of day reaches the programmed
time of regeneration. Pressing the REGEN button
again will turn off the regeneration icon and cancel the
delayed regeneration.
Immediate Manual Regeneration
Pressing and holding the REGEN button for three seconds
starts an immediate manual regeneration.
A solid regeneration icon will be displayed. The control
will immediately begin a regeneration.
Delayed Second Regeneration
Pressing and releasing the REGEN button while the
control is in regeneration will program the control for a
delayed second regeneration. A flashing x2 icon next to
the regeneration icon will appear, indicating a second
regeneration will start when the time of day reaches the
programmed time of regeneration.
Double Immediate Manual Regeneration
Back-to-Back manual regenerations are initiated by
pressing and holding the REGEN button for three seconds
while the control is in the regenerating mode. A solid x2
icon next to the regeneration icon will appear, indicating
a second manual regeneration will start immediately after
current regeneration is complete.