Overflow Line Connection

In the event of a malfunction, the regenerant tank
overflow will direct "overflow" to the drain instead of
spilling on the floor. This fitting should be on the side of
the cabinet or regenerant tank, Figure 10.
To connect the overflow line, locate the connection on
side of the regenerant tank. Insert overflow fitting into
tank and tighten with plastic thumbnut and gasket.
Attach length of 1/2-inch (1.3 cm) I. D. tubing (not supplied)
to fitting and run to drain. Do not elevate overflow line
higher than overflow fitting.
Do not tie into drain line of control unit. Overflow line
must be a direct, separate line from overflow fitting to
drain, sewer or tub with an air gap at the drain.
Figure 10
Regenerant Line Opening
Overflow Fitting
Drain Tubing
Secure hose in place
Drain
Air Gap

Electrical Connection

Note: There are no user serviceable parts in the AC
adapter, motor or the control board.
The Demand control operates on a 12-volt alternating
current power supply. This requires use of the Pentair
Water supplied AC adapter. AC adapters are available
from your supplier for different applications.
They include:
AC Adapter
Input Voltage
Standard
230V, 50/60 Hz
wall-mount
120V AC Adapters:
Make sure power source matches the rating printed on
the AC adapter.
Note: The power source should be constant. Be certain
the AC adapter is not on a switched outlet. Power
interruptions longer than eight hours may cause the
control to lose the day and time settings. When power
is restored, the control will display four dashes (- - :- -)
indicating that the day and time settings must be
re-entered.