• Regeneration failure
The system has not regenerated for more than 99 days or 7 days if the regeneration
control type has been set to day of week.
• Memory error
The controller board has a memory failure.
• Fail safe error
The valve has failed to find position in one minute.
7.2.

Manual regeneration

MANDATORY
The controller must be in service in order to enable this procedure.
7.2.1. Manual delayed regeneration
A
Press
once for delayed regeneration.
→ The regeneration starts at the programmed regeneration time. See chapter 5.3.3. Regeneration time (RT), page 14.
→ The service icon flashes.
NOTE
To cancel: press
7.2.2. Immediate regeneration
A
Press and hold
for 5 seconds to initiate immediate manual regeneration regardless from the programmed
regeneration control type.
7.2.3. To advance regeneration cycles
→ Press
to pass to the next regeneration cycle.
8 .

Maintenance

MANDATORY
Cleaning and maintenance shall take place at regular intervals in order to guarantee the proper
functioning of the complete system, and be documented in the Maintenance chapter in the User Guide
document.
MANDATORY
The maintenance and service operation must be done by qualified personnel only. Failure in
respecting this may void the warranty.