Camshaft Cycle Positions; Valve Disc Location/Function - Pentair Pro Elite Professional Series Operation Manual

Table of Contents

Advertisement

Camshaft Cycle Positions

The front end of the camshaft has an indicator cup. The
cup has slots in the outer edge and cycle numbers on the
inside face (Figure 18).
Remove the cover and look over the top of the Demand
control to view the cycle numbers. The number at the top
indicates the current cycle position of the control valve.
The corresponding slot for the number is positioned at
the optical sensor, which is rotated approximately 90
degrees out of phase.
Note: If electrical power is not available, the camshaft
can be rotated counterclockwise by hand if the motor
is removed.

Valve Disc Location/Function

Cycle Indicators:
0 = Treated Water or brine make-up if recharge cycle
has started.
1 = Backwash Cycle
2 = Regenerant Draw Cycle
3 = Slow Rinse Cycle
4 = System Pause
5 = Fast Rinse Cycle 1
6 = 2nd Backwash
7 = 2nd Fast Rinse
8 = Regenerant Refill (if system is 268r, regenerant
refill takes place before backwash cycle #1)
Figure 12 Valve
PENTAIR Pro Elite Professional Series Pro Elite Demand Instruction Manual • 15
Treated Water
Cycle Number
Treated Water
Slot
Figure 11