11 | Display Configuration
11.7.3 Further Alarm Properties
94 / 188
The value can be displayed or used for a conditional formatting.
7.
Define the text, which will be displayed in the alarm icon.
If you use the phrase <channel value>in the text, it will be substituted with the value
of the chosen channel value.
8.
Check the size, position and appearance of the alarm in the "Alarm Area Preview".
Change the appearance according to your needs with the properties described below.
Representation
– Reset Mode: Defines if the alarm is resettable. For more details, see chapter Reset-
table Alarm [} 99].
– Blink mode: Defines the blinking frequency of the alarm when displayed.
– Min. display time enable: Enables the function min. display time.
– Min. display time: Defines the minimum time an alarm will be displayed.
– Auto reset enable: Enables the function "Auto reset".
– Auto reset after: Defines the time after an alarm will be hidden, even when the condi-
tion is still true, only active for resettable alarms.
– Retrigger lock enable: Enables the function "Retrigger lock". For more details, see
chapter Resettable Alarm [} 99].
– Retrigger lock time: Defines the time in which a new rising edge of the alarm condi-
tion will not be accepted anymore, after an alarm was reset.