Bosch DDU 10 Manual page 52

Table of Contents

Advertisement

7 | Online Measurement
7.2.2 Performing the online offset calibration
52 / 188
In the channel view
DDU 10 has to be connected to RaceCon to calibrate the sensor's offset.
1.
Apply the desired physical condition to the sensor (e.g. 1 G to an acceleration sensor).
2.
Open the measurement channel's online page by double-clicking on the measure-
ment channel name in the Data Area.
3.
Enter the physical target value (e.g. 1 G) and press the 'Calibrate' button.
Calibration
target value
Initiate
calibration
The sensor's offset is now calibrated.
DDU 10
Check box to enable online
offset calibration and enter
desired physical target value
Activate switch
to enable online
calibration
Bosch Motorsport