Functions Supported By Pn Gate - Siemens SINAMICS S120 Series Function Manual

Hide thumbs Also See for SINAMICS S120 Series:
Table of Contents

Advertisement

5.6.1

Functions supported by PN Gate

PN Gate function overview
Function
Communication channels
PROFINET basic services
Accesses to process data
Consistency of the cyclic data
Network topologies
Information from the PN Gate
Activating/deactivating
Automatic address assignment
Number of IO devices
IO area in the controller
Send cycle
Communication
Function Manual, 12/2018, 6SL3097-5BD00-0BP0
5.6 Communication via PROFINET Gate
Description
Cyclic data communication:
– IRT
– RT
Acyclic data communication:
- PROFINET alarms
- Read/write data set
- TCP/IP
LLDP
DCP
SNMP
Access to the process image:
Subslot granular
Device granular
Each process data communication cycle can contain a data
component for IRT and RT communication
Line
Star
Tree
Device number
Slot number with the associated subslot numbers
IO address
Diagnostic addresses
Module ID (vendor ID and module ID)
Send cycles and update times
Activating and deactivating devices via the API without alarm
triggering
Topology-based initialization
A maximum of 64 devices
4096 bytes each, in and out
Maximum number of slots: 2048
Maximum bytes per slot/module size: 254 bytes
RT communication: 1 ms
Update times RT 2
with n = 0 to 9x send cycle
n
IRT communication
1 ms - 4 ms in increments of 250 μs minimum send cycle of
1 ms for 32 devices. It is permissible to reduce the data per
device.
Communication via PROFINET IO
137