Wall Termination Cap Installation With And Without; Optional Mechanical Damper - Heat & Glo FDN-5-PIER Installation And Operating Manual

Co-linear direct vent gas fireplaces, natural gas
Table of Contents

Advertisement

H. WALL TERMINATION CAP INSTALLATION - WITH AND WITHOUT DAMPER
Wall Termination Without

Optional Mechanical Damper

FRAMING:
8" = 11-3/4" W X 11-3/4" H
10" = 13-1/4"" W X 13-1/4" H
Figure 8H.1
Wall Termination With
Optional Mechanical Damper
MUST BE CUT IN CENTER TO
ACCOMMODATE VENT SIZE
USE APPROPRIATE HEAVY DUTY FASTENERS
Figure 8H.2
Heat & Glo • FDN-4-PIER, FDN-5-PIER, FDN-6-PIER, FDN-7-PIER Installation Manual • 16400-9803 • 2/19
24
DRILL 1/4" HOLES
TO MATCH POWER VENT BASE
INSULATION PAD
MUST BE CUT IN CENTER TO
ACCOMMODATE VENT SIZE
USE APPROPRIATE HEAVY DUTY FASTENERS
TO SECURE POWER VENT
OPTIONAL
MECHANICAL FLUE DAMPER
DRILL 1/4" HOLES
TO MATCH POWER VENT BASE
INSULATION PAD
TO SECURE POWER VENT
8 - VENTING
H
ACCESS PANEL
NEEDED FOR FUTURE
DAMPER SERVICE