NOTICE: Failure to properly caulk the roof flashing and
pipe seams may permit entry of water.
• Caulk the gap between the roof flashing and the outside
diameter of the pipe.
• Caulk the perimeter of the flashing where it contacts the
roof surface. See Figure 10.10.
• Caulk the overlap seam of any exposed pipe sections
that are located above the roof line.
Figure 10.10
Figure 10.10
F. Assemble and Install Storm Collar
CAUTION! Risk of Cuts, Abrasions or Flying Debris.
Wear protective gloves and safety glasses during instal-
lation. Sheet metal edges are sharp.
• Slide the storm collar onto the exposed pipe section
and align brackets.
• Insert a bolt (provided) through the brackets and install
nut. Do not completely tighten.
Figure 10.11 Assembling the Storm Collar Around the Pipe
Figure 10.11 Assembling the Storm Collar Around the Pipe
• Slide the assembled storm collar down the pipe section
until it rests on the roof flashing (see Figure 10.11).
• Tighten nut and make sure the collar is tight against the
pipe section.
• Caulk around the top of the storm collar. See Figure 10.12.
CAULK
Heat & Glo • ST-550TM-IPI • 2142-900 Rev. S • 3/20
G. Install Vertical Termination Cap
• Attach the vertical termination cap by sliding the inner
collar of the cap into the inner flue of the pipe section
while placing the outer collar of the cap over the outer
flue of the pipe section.
• Secure the cap by driving three self-tapping screws
(supplied) through the pilot holes in the outer collar of
the cap into the outer flue of the pipe (see Figure 10.12).
Figure 10.12
Figure 10.12