3.20.3 Connection To Display Unit; 3.20.4 Equipment Cable End Processing - JRC JMA-5312-6/6HS Installation Manual

Marine radar equipment
Table of Contents

Advertisement

3.20.3 Connection to display unit

Use 14-core composite cable 2695110056 and coaxial cable RG-10/UY to connect power control unit
NQE-3167 to display unit NCD-4530.
Among the two cables, use coaxial cable RG-10/UY to connect the radar video signal.
Fig.3.20.2 NQE-3167 terminal block

3.20.4 Equipment cable end processing

Fig.3.3 Equipment cable end processing
Fig.3.4 End processing of each cable core
3-42