Connecting the unit

6.5.1 Connecting the drinking water connection line

Prerequisite Water pressure complies with specifications (see "Unit and
28
Image: Water connection
a Softened drinking water
b Connection line
c Softened drinking water
connection
connection data")
Backflow preventer installed
Pressure-resistant connection lines suitable for tap water are
available
1. Connect the connection lines to the drinking water taps using
seals.
2. Flush the connection lines thoroughly.
3. Insert dirt filters into the water connections on the unit.
4. Connect the drinking water connection line to the unit.
5. Connect the connection line for softened drinking water to the unit.
6. Open the tap water valves and check the threaded connectors for
leaks.
7. Fill out the Start-up operation report.