a
Image: Connecting the kitchen guiding system
a RJ45 socket
b RJ45 connector
c Threaded cable connection
Prerequisite Unit dead
Housing opened
1. Pull the network cable into the unit through the cable gland.
2. Route the network cable through the two ferrite rings, with one
winding through each.
3. Connect the network cable to the unit with the RJ45 connector.
4. Register the network in the basic control setting (see "Making the
basic control setting").
5. Fill out the Start-up operation report.
b
e
Installation instructions
Connecting the unit
c
d
d Network cable
e Ferrite ring