13. Untie the string from the old Lift Motor Wire and discard the old cable.
14. Tie the end of the string at the base of the Cable Mast to one end
of the replacement Lift Motor Wire. Hold the other end of the string and
carefully pull the new Lift Motor Wire through the Cable Mast.
NOTICE: Hold the Input/Output (I/O) Cable so that you do not pull it
out of the Console Mast. Do not crimp the cables.
15. Connect the new Lift Motor Wire to the Lift Motor Wire from the Main
Frame. Reconnect the other cable from the Mast and the Main Frame.
NOTICE: Do not crimp the cables. This step may require two people.
16. Reassembly is the reverse procedure.
NOTICE: Do not crimp the cables. Untie the string from the Lift
Motor Wire. Do not allow the cables to fall down into the
Console Mast.
Be sure the tabs in the Top Shroud snap into the Main
Assembly.
17. Inspect your machine to ensure that all hardware is tight and compo-
nents are properly assembled.
Do not use until the machine has been fully assembled and
inspected for correct performance in accordance with the
Owner's Manual.