Nautilus E618 Service Manual page 84

Table of Contents

Advertisement

8. Using a 14mm socket and ratchet, remove the Lock Nut from the Crank
Arm.
9. Thread the Crank Puller into the Crank Arm. When the Crank Puller is
in the correct position, only 1-2 threads on the outer portion (CP2) of the
Crank Puller should show.
Note: B e sure the end of the Bolt (CP1) of the Crank Puller is flush with
the Nut (CP2) as shown, before use.
CP1
10. Using a wrench, turn the inner portion (CP3) of the Crank Puller
clockwise. The Crank Arm will slide off as it is tightened.
Note: Be advised that it may take a lot of force to get the Crank Puller to
start to slide off the Crank Arm.
11. Using a #2 Phillips screwdriver, remove the 7 indicated screws (*) from
the Left Shroud and remove them. Remove the bottom screws first, and
then the top screws. Slowly remove the Left Shroud.
NOTICE: Be sure not to crimp any cables.
12. Bend the edges of the Top Shroud to disengage the inside tabs from
the Main Assembly, and slide the Shroud Cap and Upper Shroud up the
Mast.
13. Using a #2 Phillips screwdriver, remove the 7 indicated screws (arrows
indicate screws below the Upper Shroud) that secure the Left Shroud.
Remove the lower screws first. Slowly remove the Left Shroud.
CP2
CP3
Upper Shroud
84