National Instruments VXI-MXI-Express Series User Manual page 58

Hide thumbs Also See for VXI-MXI-Express Series:
Table of Contents

Advertisement

Inverting CLK10
CLK10 Termination
Front Panel/SMB Trigger Input Termination
Parallel termination is not necessary when the signal is driven by a 50 Ω source,
Note
such as a NI VXI-8360T/LT controller.
© National Instruments
If the front panel SMB connector EXT CLK is configured as an output this
software setting provides the capability to invert the clock output. This
setting can be found in the hardware configuration panels in MAX as
shown in Figure B-4.
Figure B-4. Inverting the CLK10 Signal through MAX
If the front panel SMB connector EXT CLK is configured as an input
this software setting can enable 50 Ω parallel termination. This setting
can be found in the hardware configuration panels in MAX, as shown in
Figure B-4.
Optional software enabled 50 Ω parallel termination is available for the
front panel trigger input. This setting can be found in the hardware
configuration panels in MAX, as shown in Figure B-4.
Appendix B
Advanced Hardware Configuration Settings
B-7
VXI-MXI-Express Series User Manual