NI VXI-8360T Front Panel Features
Front Panel
© National Instruments
•
Eight front panel status LEDs
–
FAILED—Indicates the NI VXI-8360T failed power on
diagnostics.
–
SYSFAIL—Indicates the VMEbus SYSFAIL line has been
asserted by a device on the backplane.
–
ONLINE—Indicates the board is detected by the
NI-VXI/VISA driver.
–
ACCESS—Indicates a VXI bus master is accessing the
NI VXI-8360T.
–
CB—Indicates the circuit breaker has tripped from an over
current condition on the +5.0 V
–
ACT—Indicates bus activity on the MXI-Express link.
–
PWRGD—Indicates the on board power supplies are in
regulation.
–
LINK—Indicates the MXI-Express link connecting the host
computer to the NI VXI-8360T has been established.
•
TRIG/CLK PORT A(B)—These ports allow the user to
daisy-chain the 8 TTL triggers and/or CLK10 between multiple
chassis.
•
CABLE STATUS LED—Indicates if the cable connections to
the TRG/CLK ports are correct.
–
Off—Indicates no cables are connected to the TRIG/CLK
PORT A(B) ports.
–
Blinking Red—Indicates incorrect trigger cable connection.
–
Solid Green—Indicates correct trigger cable connection.
•
Three front panel SMB connectors for:
–
Trigger input
–
Trigger output
–
CLK10 I/O
•
One MXI-Express x1 connector
1-3
Chapter 1
Features
rail of the NI VXI-8360T.
DC
VXI-MXI-Express Series User Manual
Introduction