Chapter 2
Installation and Configuration
Note
If you change any configuration settings, you will need to run Resman to apply the
changes.
You can also run Resman for all VXI systems at once in MAX by selecting Tools»
Note
NI-VXI»VXI Resource Manager.
If you are using extenders such as MXI-2 to create a multichassis system, you may
Note
need to run Resman before configuring some of your devices.
VXI-MXI-Express Series User Manual
3.
Verify the configuration of your VXI system by right-clicking the
device in the configuration tree, and selecting Properties or
Hardware Configuration, as shown in Figure 2-1.
Figure 2-1. Right-Clicking on a VXI System in MAX
4.
Run Resman by either clicking the Run VXI Resource Manager button
in the toolbar or right-clicking on the VXI system, as shown in
Figure 2-1.
If Resman encounters any issues during configuration, it will report
errors in Max under the system listing.
5.
Verify the configuration, as needed, through the interactive control
utility, VISAIC (Start»Programs» National Instruments»VISA»
VISA Interactive Control), as described in Chapter 3,
Your
Application.
2-6