National Instruments VXI-MXI-Express Series User Manual page 49

Hide thumbs Also See for VXI-MXI-Express Series:
Table of Contents

Advertisement

Appendix A
Specifications
Shock and Vibration
VXI-MXI-Express Series User Manual
Operating Environment
Ambient temperature range ....................0 to 55 °C
Relative humidity range..........................10% to 90%
Storage Environment
Ambient temperature range ....................–40 to 85 °C
Relative humidity range..........................5% to 95%
EMI .........................................................FCC Class A verified, EC verified
Operational shock ...................................30 g peak, half-sine, 11 ms pulse
Random vibration
Operating .........................................5 to 500 Hz, 0.3 g
Nonoperating ...................................5 to 500 Hz, 2.4 g
(Tested in accordance with
IEC-60068-2-1 and
IEC-60068-2-2: meets
MIL-PRF-28800F Class 3 low
temperature limit and
MIL-PRF-28800F Class 2 high
temperature limit.)
(Tested in accordance with
IEC-60068-2-56.)
(Tested in accordance with
IEC-60068-2-1 and
IEC-60068-2-2; meets
MIL-PRF-28800F Class 3 limits.)
(Tested in accordance with
IEC-60068-2-56.)
(Tested in accordance with
IEC-60068-2-27; meets
MIL-PRF-28800F Class 2 limits.)
(Tested in accordance with
IEC-60068-2-64. Nonoperating
test profile exceeds the
requirements of
MIL-PRF-28800F, Class 3.)
A-14
rms
rms
ni.com