2.2.3 Dimensional drawing and mounting method

Model V700-HMD11-1
5
Status indicator
Mounting method
(1) Front mounting
(2) Back mounting
Insert the enclosed nuts into areas A, and mount the head.
∗ Be sure to limit the tightening torque for the M4 screws to 1.2 N-m or less.
∗ Do not apply an organic solvent such as thread glue to the threads. Otherwise, cracking can occur on
the case.
2-
4.5
2- 10
4-R1
(mounting hole)
27
6
53
20
2-M4
Center of coil
27
53
A
A
Nut
Nut
6, length 1000
Lock screw
45.5
Case material
Filler resin
Cable
28 0.2 40
Section 2