Test - Omron V700-HMD13 series User Manual

For rfid system for semi conductor device fabrication line
Hide thumbs Also See for V700-HMD13 series:
Table of Contents

Advertisement

Section 4
Data Read/Write with ID Tag

4.4.5 Test

This command is for verifying loop back communications performance between the upstream controller and
IDRW head. Upon receiving this command, the IDRW head returns the response code and test data of
command as a response to the upstream controller.
This command can be conveniently used to verify communications reliability during system designing, or to
find a cause of problem during troubleshooting.
Command frame structure
Unlike the read, write, same write and byte write commands, this command consists of two characters.
A test data is input as a parameter.
Command
"1"
"0"
Response frame structure
The response code (normal completion "00") as well as the test data received with the command are
returned. If an error should occur, an error code is returned as a response code.
Response code
"0"
"0"
<Example of command execution>
Command : 1 0 1 2 3 4 5 6 7 8 [CR]
Test command
Response : 0 0 1 2 3 4 5 6 7 8 [CR]
Response code
V700-L11
46
User's Manual
Test data
(Data1)
Test data
(Data1)
Test data
Test data
CR
(Data n)
$0D
CR
(Data n)
$0D