System Configuration - Omron V700-HMD13 series User Manual

For rfid system for semi conductor device fabrication line
Hide thumbs Also See for V700-HMD13 series:
Table of Contents

Advertisement

1.2 System configuration

By combining an IDRW head and a link unit, various system configurations (connection configuration, supply
voltage).
Unit-to-unit configuration
• 1:1 connection (RS-232C)
• 5 VDC power supply
• 1:1 connection (RS-232C)
• 24 VDC power supply
• 1:N connection (RS-232C)
• 24 VDC power supply
For a 1:N connection involving a link unit, it is necessary to add an normal controlled RS signal from an
upstream controller to a CS signal. The RS signal must be turned OFF within 15 msec after completion of
data transmission. Otherwise, this configuration does not operate correctly.
(For details, refer to Sec. 2.3.2 Interface specifications.)
Interfacing with upstream controller: RS-232C
IDRW head/link unit connection configuration
ID tag
IDRW head
ID tag
IDRW head
ID tag
IDRW head
ID tag
RS-485
IDRW head
RS-485
ID tag
IDRW head
Precautions for trouble-free operation
System Features and Configuration
RS-232C
5 VDC
Link unit
RS-232C
24 VDC
Link unit
RS-232C
24 VDC
Link unit
24 VDC
Link unit
Max. 31 units
24 VDC
Section 1
Upstream
controller
Upstream
controller
Upstream
controller
V700-L11
9
User's Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

V700-hmd11-1V700-l11V700-d23p41-1

Table of Contents