Limitations about Model V700-HMD13

When a Model V700-HMD13 (not Model V700-HMD13 ) is used to configure a system, there will be the
operating limitations described below.
<Description of limitations>
Among the memory page1 1 through 30 on an ID tag, page 1 through 12 are available to the user. Do not
access to page 13 to 30 with commands. However, note that data read/write is possible with a plurality of
pages as a block.
(1) Operation to read data in page 1 through 30 as a block
The data read process is divided into two steps: read of page 1 through 14 and that of page 15
through 30.
0100 0000FFFC [CR]
0100 FFFF0000 [CR]
(2) Operation to write data in page 1 through 30 as a block
0200 0000FFFC (write data with page 1)(write data with page 2)
0200 FFFF0000 (write data with page 15)(write data with page 16)
(3) Operation to write data in page 3 through 30 as a block
The data write process is divided into two steps: write of page 3 through 14 and that of page 15
through 30.
0200 0000FFF0 (write data with page 3)(write data with page 4)
0200 FFFF0000 (write data with page 15)(write data with page 16)
A RFID system configuration using Model V700-HMD13A will serve free of the above-mentioned
limitations.
V700-L11
4
User's Manual
... (write data with page 14) [CR]
... (write data with page 30) [CR]
... (write data with page 14) [CR]