Idrw Head Is Directly Connected To Upstream Controller; No Response (Response Not Yet Received), Or, Occurrence Of Illegal Characters; Response Is Available (Response Code Is Other Than "00") - Omron V700-HMD13 series User Manual

For rfid system for semi conductor device fabrication line
Hide thumbs Also See for V700-HMD13 series:
Table of Contents

Advertisement

Section 7
Troubleshooting
If a fault should occur, first thoroughly study the symptom in order to be able to correctly judge the
reproducibility of a problem, and interaction with other associated equipment. Thus, find an appropriate
remedy.
7.1 IDRW head is directly connected to upstream
controller
7.1.1 No response (response not yet received), or, occurrence of ille-
gal characters
Check the following points.
Supply voltage (5 VDC
Cable connection (pin arrangement on the upstream controller side, wiring connection/disconnection of connection cable, etc.)
Communications protocol settings on upstream controller (Baud rate, data format)

7.1.2 Response is available (response code is other than "00")

According to the response code in response data, check the following points.
Error in communication with upstream controller side
Response code
"10"
"11"
"12"
"14"
"18"
Communications error
Response code
"70"
"71"
"72"
"7A"
"7B"
"7E"
"7F"
System error
Response code
"7C"
V700-L11
56
User's Manual
±
5% on connector)
Name
Parity error
• Communication protocol settings on upstream controller (data format)
• Routing of RS-232C cable (adverse effect by external noise interference)
Framing error
• Noise environment on power line of IDRW head
Overrun error
Format error
• Command format
(type and number of characters, number of pages, inter-command spacing,
Frame length error
etc.)
Name
Communications error
• Mounting distance between ID tag and IDRW head(s)
• Noise environment around IDRW head (correct the location of head)
• Spacing to another IDRW head
Verify error
• Life of ID tag in terms of number of rewrite operations (100,000 cycles)
ID tag missing error
• Mounting distance between ID tag and IDRW head(s)
• Spacing to another IDRW head
Address designation error
• Wrong page, or address/number of bytes with executed command
Out of write area error
• Mounting distance between ID tag and IDRW head(s)
ID system error (1)
• Operating environment of tag (damaged ID tag by misoperation or misuse)
• Model and specifications of ID tag used
ID system error (2)
Name
Antenna hardware error
• (The equipment may have been damaged.)
Typical checkpoint
Typical checkpoint
Typical checkpoint
Typical checkpoint

Advertisement

Table of Contents
loading

This manual is also suitable for:

V700-hmd11-1V700-l11V700-d23p41-1

Table of Contents