RTK ASSIST is available as soon as the rover receiver has at least one valid RTK solution and
has received the RTK ASSIST correction data. If an RTK correction outage occurs, then RTK
ASSIST will maintain RTK mode until the subscription-permitted RTK ASSIST duration is
exceeded. A shorter, user-defined RTK ASSIST time out can also be set using the
RTKASSISTTIMEOUT command. Normal RTK operation will seamlessly resume if RTK cor-
rections are restored at any point while RTK ASSIST is operating.
RTK ASSIST will report the RTK solution type that was present before RTK corrections were lost,
unless the estimated solution standard deviation exceeds the threshold set by the
RTKINTEGERCRITERIA command. If this occurs, then integer RTK solutions will be down-
graded to their float RTK equivalent.
RTK ASSIST is enabled by default, but can be disabled using the RTKASSIST command. To mon-
itor the status of RTK ASSIST, view the RTKASSISTSTATUS log.
Refer to the
Agriculture Commands and Logs Reference Manual
RTK ASSIST typically provides 4 cm accuracy. However, if the RTK outage occurs during
the first 30 minutes of receiver operation, the position accuracy provided by RTK ASSIST
may be lower.
Additional information about enabling and using RTK ASSIST is available in the RTK
ASSIST Application Note (available from our website:
tel.com/assets/Documents/Bulletins/APN-073-RTK-ASSIST.pdf).

3.10 Logging Using NovAtel Connect

NovAtel Connect is a computer program used to configure and monitor NovAtel receivers.
The Logging Control Window in NovAtel Connect provides an interface to configure logging and
to collect logs from the receiver. The collected logs can be output to one of the receiver com-
munication ports or stored on the computer running NovAtel Connect.
For details about using NovAtel Connect, refer to the Help file available within NovAtel
Connect.
NovAtel Connect version 2.0 or greater is required for OEM7 receivers. Download
the latest NovAtel Connect software and documentation from
www.novatel.com/novatel-connect.
To open the Logging Control window:
1. Open NovAtel Connect.
2. Establish a connection to the receiver.
SMART7 Installation and Operation User Manual 0C
for log and command details.