Section 5. Programming Reference
Command Structure
Command Function
Input to Printer
Printer Output
Special Notes
Page 5-122
Sensor Type
<ESC>IGa
a
=
0
Reflective (Eye Mark) sensor
1
See-thru (transmissive) sensor
2
Sensor not used
Example:
See above
Placement:
Separate data stream sent to printer
Default:
Default value set by <ESC>PG command
To select the label sensing method for a job.
IG1
There is no printer output as a result of this command
1. When power is cycled, the value set by this command is lost and
replaced by the default value stored in the EEPROM.
2. To change the value stored in the EEPROM, use the <ESC>PG
Printer Setting command or use the Printer Setting Utility program
contained on the CDROM shipped with the printer.
9001074 Preliminary