Calendar Set

<ESC>WTaabbccddee
aa
=
Year (00-99)
bb
=
Month (01-12)
cc
=
Day (01-31)
dd
=
Hour (00-23)
ee
=
Minute (00-59)
Example:
<ESC>WT9101311200
Placement:
This command must be sent in an independent data
stream.
Default:
None
To set the time and date of the printer's internal clock.
WT9312251300
There is no printer output for this command. It sets the current date to
December 25, 1993 and the current time to 1:00 PM in the printer.
PN 9001074 Preliminary