Field Service Ver. 2.0 Jul. 2009
19.5.10
C1003: PK communication error
Punch control board (PKDB)
Step
1
Disconnect and then connect the power
cord. Turn OFF the main power switch, wait
for 10 sec. or more, and turn ON the main
power switch.
2
Rewrite the firmware.
3
Change PKDB
4
Change FSCB
19.5.11
C1004: FNS communication error
FS control board (FSCB)
Step
Disconnect and then connect the power
cord. Turn OFF the main power switch, wait
1
for 10 sec. or more, and turn ON the main
power switch.
2
Rewrite the firmware.
3
JSCB F1 conduction check
4
JSCB F2 conduction check
5
Change FSCB
19.5.12
C1005: ZU communication error
ZU control board (ZUCB)
Step
Disconnect and then connect the power
cord. Turn OFF the main power switch, wait
1
for 10 sec. or more, and turn ON the main
power switch.
2
Rewrite the firmware.
3
Change ZUCB
Y110571-1
Relevant parts
Action
Relevant parts
Action
Relevant parts
Action
Service Manual
FS control board (FSCB)
WIRING DIAGRAM
Control signal
—
—
—
—
WIRING DIAGRAM
Control signal
—
—
—
—
—
WIRING DIAGRAM
Control signal
—
—
—
19. TROUBLE CODE
Location (Electri-
cal component)
—
—
—
—
Location (Electri-
cal component)
—
—
—
—
—
Location (Electri-
cal component)
—
—
—
763