8. Trouble code
8.3
Solution
8.3.1
C0001: LCT communication error
PC control board (PCCB)
Step
Turn OFF the main power switch, wait for
1
10 sec. or more, and turn ON the main
power switch.
2
PCCB replacement
8.3.2
C0209: LCT elevator motor failure
Elevator motor (M5)
Elevator motor pulse sensor (PS10)
Step
Check the motor and sensor connectors for
1
proper connection, and correct as neces-
sary.
Check the connector of motor for proper
2
drive coupling, and correct as necessary.
3
PS10 I/O check, sensor check
4
M5 operation check
5
REYB replacement
6
PCCB replacement
36
Relevant electrical parts
Action
Relevant electrical parts
Action
Service Manual
Field Service Ver. 1.0 Jul. 2007
WIRING DIAGRAM
Control signal
—
—
Relay board (REYB)
PC control board (PCCB)
WIRING DIAGRAM
Control signal
—
—
REYB PJ2REYB<A>-5 (ON)
REYB PJ2REYB<B>-6 to 7
—
—
Location
(Electrical
components)
—
—
Location
(Electrical
components)
—
—
PC-405 K-5
PC-405 K-7
—
—
Y109030-4