Solution; C1004: Fns Communication Error; C1182: Shift Motor Drive Failure - Olivetti JS-505 Service Manual

Option printer
Table of Contents

Advertisement

Field Service Ver. 1.0 Jun. 2008
7.2

Solution

7.2.1

C1004: FNS communication error

JS control board (JSCB)
Step
Disconnect and then connect the power
cord. Turn OFF the main power switch, wait
1
for 10 sec. or more, and turn ON the main
power switch.
Rewrite firmware using the compact flash
2
card.
3
Change JSCB
7.2.2

C1182: Shift motor drive failure

Shift motor (M2)
Shift home sensor (PS6)
Step
Check the M2 connector for proper con-
1
nection and correct as necessary.
Check the connector of M2 for proper
2
drive coupling and correct as necessary.
3
PS6 I/O check, sensor check
4
M2 operation check
5
Change JSCB
Y109081-8
Relevant electrical parts
Action
Relevant electrical parts
Action
Sevice Manual
WIRING DIAGRAM
Control signal
JS control board (JSCB)
WIRING DIAGRAM
Control signal
JSCB PJ7-18 (ON)
JSCB PJ4-1 to 4
7. Malfunction code
Location
(Electrical
component)
Location
(Electrical
component)
JS-505 F-3