Mechanical Adjustment; Pi Displacement Adjustment (With Pk-512/Pk-513 Installed) - Olivetti PI-503 Service Manual

Option printer
Table of Contents

Advertisement

Field Service Ver. 2.0 Aug. 2007
8.

Mechanical adjustment

8.1

PI displacement adjustment (with PK-512/PK-513 installed)

• Conduct this adjustment when the punch position is displaced when feeding from PI.
NOTE
• Punch hole deviation correction must be completed before making this adjust-
ment.
See P.15 of the PK-512/513 service manual.
• Centering adjustment of the tray 1/2/3/4 must be completed before making this
adjustment.
See P.565 of the main body service manual.
See P.566 of the main body service manual.
• In the PI displacement adjustment, adjust the tray /Up, and then adjust the tray /
Lw.
1. Set three sheets of paper in the tray of the PI, and then feed them in the punch mode
as samples.
2. Fold the sheets in half at the center and check the misalignment of the punch holes.
Y107982-5
<In the upper tray case>
[2]
3. Release the hook [1], and remove
[1]
A07VF3C503DA
<In the lower tray case>
3. Remove the adjustment cover in the
[2]
[1]
A07VF3C504DA
Service Manual
8. Mechanical adjustment
the adjustment cover [2].
same way as the upper tray case.
Remove two screws [1], slide the
side guide plate /Rr [2] to the front,
and remove it.
23

Advertisement

Table of Contents
loading

Table of Contents