Fitting a Remote GKP

When fitting the GKP remotely to either a cubicle or panel mount it must be fitted to a flat surface. Maximum cable length < 3 meters.
 7001-00-00 – includes the GKP only
 7001-00-01 - includes the GKP, 3m connection lead and screws.
If ordered and supplied with the inverter the connection lead is NOT supplied, to order the lead the part number is LA501991U300.
Cut out details:
AC30 series Variable Speed Inverter
GKP – Reverse side
The yellow dotted line is the cutout
detail to allow remote fitting the
connection lead, also shows screw
hole details.
Use M3 x 10 self tapping screws.
Connection lead RS232/REM OP
STA with a Steward 28A2025-OAO
connector.
All measurements in millimeter.
Reverse side of the
Gasket
GKP
4-40