STO Technical Specification

INPUTS SPECIFICATION

STO A Input and STO B Input comply with IEC61131-2. Note: inputs do not have hysteresis.
Recommended input voltage for low level:
Recommended input voltage for high level:
Typical input threshold voltage:
Indeterminate input range:
Absolute maximum input voltage:
Typical input current @ 24V
Fault detection time
Response time
5
Conditions in which the STO inputs are operative:
4
A fault is defined in this context as STO A Input and STO B Input being sensed in opposite logic states.
5
Response time is the time from the first STO input becoming active (voltage level is low) until torque production has ceased
AC30 series Variable Speed Inverter
:
4
0V to +5V
+21.6V to +26.4V
+10.5V
+5V to +15V. Function is undefined.
-30V to +30V
9mA
2.3sec typical;
< 1.6sec will not generate a fault
> 3.0sec will generate a fault.
> 2ms
6ms typical
< 10ms
All, i.e. STO cannot be disabled in any condition