3-2
Product Overview

Control Features

The inverter is fully featured when controlled using the optional Keypad (or a suitable pc programming tool).
The 'General' control features below are not user-selectable when the unit is controlled using the analog and digital inputs and outputs.
General
Output Frequency
Switching Frequency
Voltage Boost for V/F control
Motor Control Modes
Skip Frequencies
Preset Speeds
Stopping Modes
S Ramp and Linear Ramp
Raise/Lower
Jog
Diagnostics
Protection
Trip Conditions
Current Limit
Dual Rating
Inputs/
Analog Inputs
Outputs
Analog Outputs
Digital Inputs
Digital I/O
Relay Outputs
Table 3-1 Control Features
Limited to Switching Frequency divided by 8, with a maximum of 590Hz.
e.g.
for 4kHz switching frequency it is 4000/8 = 500Hz,
for 16kHz switching frequency it is 590Hz. Refer to Parker SSD for higher output frequency.
Derating of output current may apply, refer to Appendix F Technical Specifications.
Minimum 2kHz.
Maximum 8kHz – 16kHz dependent on frame size and motor type (Induction or PMAC)
0-25%
Induction motor: VHz control, Sensorless Vector Control, or Closed Loop Vector Control (with
encoder). Sensorless and Closed Loop Vector require autotune for IM.
Induction motor : Closed Loop Vector Control (with Resolver)
PMAC motor: Sensorless Vector Control
PMAC motor: Sensorless Vector Control or Closed Loop Vector Control (with resolver and
encoder (with power on constraints)
Skip frequencies with adjustable skip band width
User selectable preset speeds
Ramp, Coast, DC Injection, Quickstop
Symmetric or asymmetric ramp up and down rates
Programmable MOP function
Programmable jog speed
Full diagnostic and monitoring facilities
Output short line to line, and line to earth
Overcurrent > 220% HD current
Stall
Heatsink overtemperature
Motor Thermistor overtemperature (using optional GPIO)
Overvoltage and undervoltage
Adjustable 110% (Normal Duty) or 150% (Heavy Duty)
180% shock load limit (Heavy Duty)
Inverse Time
Normal duty (110% overload for 60s)
Heavy duty (150% overload for 60s)
2 configurable inputs; voltage or current
2 configurable outputs; voltage or current
3 configurable 24V dc inputs
4 configurable 24V dc open collector outputs/digital inputs
2 configurable relay output
AC30 series Variable Speed Inverter