Remove The Pressure Control Valve - Kärcher AP 100 M Service Manual

Table of Contents

Advertisement

5.8 Remove the pressure control valve

Note
The pressure control valve is set by the manufacturer
and cannot be adjusted.
The pressure during high pressure operation is ap-
prox. 41 bar, during low pressure operation, it is ap-
prox. 14 bar.
To decrease the pressure, the pressure control valve
can be turned in clockwise direction; the decrease al-
ways affects both pressures.
The pressure control valve may only be tightened by
max. three revolutions.
Preliminary tasks:
Remove the wheel support.
1 High-pressure pump
2 Return connection for fresh water
3 Pressure relief valve
Unscrew the fresh water return hose.
Remove the high pressure hose.
Remove the high pressure pump.
38
English 5.906-508.0 Rev. 00 (11/10)
1 Pressure relief valve
2 High-pressure pump
3 High pressure hose
Unscrew the pressure control valve from the high
pressure pump.
Installation in reverse order
Note
After the assembly, check all hoses for leaks.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ap 50 m

Table of Contents