1 Suction turbine plate
2 Fastening screw
3 High pressure/low pressure solenoid valve
Unscrew the fastening screws of the suction tur-
bine plate.
Raise the suction turbine plate.
Disconnect all the connecting cables of the suction
turbine.
1 Fastening nut of the protective conductor
2 Connecting block
3 Fastening screw
Unscrew the fastening screws of the terminal strip.
Remove the terminal block.
Unscrew the protective conductor from the suction
turbine plate.
Remove all the cable ties.
1 Fresh water tank
2 Water filter
3 Supply hose for fresh water
4 Hose clip
Loosen the hose clamps on the fresh water reser-
voir and on the water filter.
Remove the fresh water supply hose.
1 Fresh water tank
2 Fresh water return hose
3 Hose clip
Loosen the hose clamp on the fresh water reser-
voir.
Remove the fresh water return hose.
Loosen the hose clamp on the fresh water drain
hose.
Remove the fresh water drain hose.