Table 10: Menus and Submenus (Part 3 of 9)
Level 1
Level 2
(LCD Screen Name)
Control Setup
Fan Off Delay*
(Cont)
Frost Protection
Dehumidification Enable*
Aux Mode
Load Shed Rate Limit
Load Shed Adjust
Fan Alarm Delay
Fan Alarm Delay
Fan Alarm Action*
Fan Alarm Reset*
Fan Runtime Limit
Fan Runtime Reset*
Supply Air Temperature Alarm Offset
Supply Air Temperature Alarm Delay*
Unocc Low Speed Fan
Inputs
BI1 Configuration
BI2 Configuration
Supply Temp Type*
Supply Temp Sensor*
Supply Temp Offset*
Zone Temp Sensor
Zone Temp Offset
TEC3000 Series On/Off or Floating Fan Coil and Individual Zone Thermostat Controllers with Dehumidification
Level 3
(Default Values)
30 seconds
Yes
No
Not Used
0.066°F
4°F
0 seconds
0 seconds
Enable
No
0 hours
No
0°F
300 seconds
Disable
Disabled
Disabled
Analog Sensor
Nickel
0
Nickel
0
Capability Installation Instructions
36
1
Available Values
0 to 120 seconds
* Fan coil units only
Yes or No
Yes or No
* Fan coil units with humidity sensor
Not Used, Occupied NO, Occupied NC,
Occupied Fan NO, Occupied Fan NC, On,
Off
0 to 1°F (0 to 0.5°C)
0 to 8°F (0 to 4°C)
0 to 300 seconds
0 to 300 seconds
Enable or Shutdown
* When Fan Alarm Delay is greater than 0
Yes or No
* When Fan Alarm Delay is greater than 0
0 to 9,000 hours
Yes or No
* When Fan Runtime Limit is greater than
0
0 to 10°F (0 to 5.5°C)
300 to 3,600 seconds
* When Supply Air Temp Alarm Offset is
greater than 0
Enable or Disable
*When Fan Type = Multi-Speed Fan
(only available in versions 3.0.4 or
greater)
Disabled, Open Window, Open Door, Fan
Lock, Service, Dirty Filter, Motion NC,
Motion NO, Temp Occ, Occupancy
Disabled, Open Window, Open Door, Fan
Lock, Service, Dirty Filter, Motion NC,
Motion NO, Temp Occ, Occupancy
Analog Sensor, Heating NC, Cooling NC
* Non four-pipe units only
Nickel, Platinum, A99B, 2.25k ohm
negative temperature coefficient (NTC),
10k ohm NTC, 10k ohm NTC Type 3
* SAT Mode = Analog Sensor,
non four-pipe
-5 to 5 (°F or °C based on Units setting
under Display Settings menu)
* Analog Sensor
Nickel, Platinum, A99B, 2.25k ohm NTC,
10k ohm NTC, 10k ohm NTC Type 3
-5 to 5 (°F or °C based on Units setting
under Display Settings menu)