8.6 Replacing the Leg Actuators

This procedure should only be performed by a
qualified technician.
If the legs A of the patient lift do not open and
close properly, it may be necessary to replace one or
both of the leg actuators.
1195052-B
1. Test the operation of the legs:
Press the close button on the hand control to close
the legs.
Press the open button on the hand control to open
the legs.
2. While holding on to the mast handles B, carefully tip
the patient lift back until it rests on the floor.
It is necessary to remove both small base covers
D before removing the large base cover F.
3. Remove the sixteen screws C that attach the small base
covers to the base.
4. Remove the eight pan head screws E that attach the
large base cover to the base.
If the left or the right leg of the patient lift does
not operate properly, perform the following
steps on the side of the base necessary to
replace the actuator. If both legs do not operate
properly, perform this replacement procedure on
both sides of the base.
5. Locate and disconnect the leg actuator lead wires.
The actuator lead wires will be visible after the
large base cover is removed.
6. Remove the socket head screw and washer that attach
the leg actuator to the base.
7. At the other end of the actuator, remove the socket
head screw and nut that attach the leg actuator to the
leg bracket.
8. If necessary, repeat STEPS 5-7 on the opposite side of
the base to remove the other leg actuator.