Communications - ADEMCO VISTA-50P Quick Start Manual

Partitioned security system with scheduling, step-by-step programming procedure, single and multiple partition programming forms system worksheets
Hide thumbs Also See for VISTA-50P:
Table of Contents

Advertisement

Refer to the PARTITION-SPECIFIC program fields for programming each partition's variable
2 * 0 0
NUMBER OF PARTITIONS
Enter 1-8
2 * 0 1
DAYLIGHT SAVINGS TIME [04, 10]
START/END MONTH
00-12; if no daylight savings time, enter 00,00
2*02
DAYLIGHT SAVINGS TIME
START/END WEEKEND #
Enter 1-7. 1=first; 2=second; 3=third; 4=fourth; 5=last; 6=next to
last; 7=3rd from last [1,5; 1st Sunday in April, last in Oct.]
2 * 0 5
AUTO-ARM DELAY
2 * 0 6
AUTO-ARM WARNING PERIOD
2 * 0 7
AUTO-DISARM DELAY
2 * 0 8
ENABLE FORCE ARM FOR
AUTO-ARM
2 * 0 9
ENABLE OPEN/CLOSE
REPORTSBY EXCEPTION
2 * 1 0
ALLOW DISARMING ONLY
DURINGARM/DISARM WINDOWS
2 * 1 1
ALLOW DISARM OUTSIDE WINDOW
IF ALARM OCCURS
Used only if field 2*10 (partition-specific field) is set to "1". If
this field is enabled ("1") the system can be disarmed outside
the disarm window if an alarm has occurred. If "0", disarming
can only be done during the disarm window. If field 2*10 is set
to "0" for a partition, this field has no effect for that partition.
SCHEDULING RELATED DIALER REPORTS
2 * 1 3
2 * 1 4
1st Digit
2nd Digit
|
|
Early opening report code
|
|
Early closing report code
|
|
Late opening report code
|
|
Late closing report code
|
|
No opening (late to open) report code
|
|
No closing (late to close) report code
|
|
Auto-arm failure report code
|
|
Access schedule changed report code
3rd Page Programming Fields
(press *94) PARTITIONING SETUP FIELDS
c h a r a c t e r i s t i c s .
[1]
|
|
Start
End
[1, 5]
|
Start | End
Partition-Specific
Partition-Specific
Partition-Specific
Partition-Specific
Partition-Specific
Partition-Specific
[0]
2 * 1 8
ENABLE GOTO FOR THIS PARTITION
2 * 1 9
USE PARTITION DESCRIPTORS
0=disable; 1=enable
2 * 2 0
ENABLE J7 TRIGGERS BY
PARTITION
2 * 2 1
ENABLE SUPERVISION PULSES FOR LRR
TRIGGER OUTPUTS
Used for supervised connection to 7920SE.
Enter 0 to disable or 1 to enable the listed outputs.
F= Fire; B= Burglary; S= Silent panic/duress
SUMMARY OF PROGRAMMING COMMANDS
• To enter program mode, enter installer code +
[8] + [0] + [0]
• To set standard defaults, press *97
• To set communication defaults, press *94 +
one of the following: *80=low speed; *81=Ademco
Express; *82=Ademco High Speed; *83=Ademco's
Contact ID
• To change to next page of program fields,
press *94
• To return to previous set of fields, press *99
• To erase account & phone number field
entries, press [*] + field number + [*]
• To assign zone descriptors, press #93 +
follow menu prompts
• To add custom words, press #93 + follow menu
prompts
• To enter Installer's Message, press #93 +
follow menu prompts
• To exit program mode, press *99 OR *98: *99
allows re-access to programming mode by installer
code. *98 prevents re-access to programming
mode by installer code.
Partition-Specific
[0]
Partition-Specific
[000]
|
|
F B S
– 17 –